CCD Observing Log of Ritter Observatory
Page  1 of  1

Echelle settings UT Date: 2007 Jan 17
Observer:   KSB/NDM
LDS Settings
X-Disp Tilt: 235.0 λc: Hα Exposure: 20070117.*
Temp. (°C):  2
RH (%):   70
Grating: 6 λc: Hα Tilt: 4o
Echelle Tilt: 21.95 Slit: 275 Sky Conditions:   clear w/ some light cirrus, cold
Slit: 255 Temp.: -93.5oC Focus: 5.81


Exp #
Start Time
(UT)
Dur
(s)
HA
Start
E/L
Object
Sp. Type
V
Mag
ADU's
(/pix)
Comments
1-5
22:20
0
zenith
E
bias


77
dome a bit cranky about opening in the cold...
6-10
22:38
5 "
E
flat


3783

11
22:51
300
"
E
Th-Ar


105

12
23:15
300
+4:43
E
alpha Cyg
A2 Ia
1.25
177
#13  Th-Ar   23:24  ; large hour angle - seeing is so-so
14
23:50
2400
+3:35
E
pi Aqr
B1 Ve
4.66
99
#15  Th-Ar   00:33  ; focus very poor
16
0:51
1800
+3:06
E
rho Cas
G2 IaOe
4.4
121
#17  Th-Ar   01:25  ; tweaked focus
18
1:40
2700
+3:04
E
omicron Cas
B5 III
4.54
147
#19  Th-Ar   02:28
20
2:43
900
+3:56
E
gamma Cas
B0 IVe-sh
2.47
259
#21  Th-Ar   03:01
22
3:17
600
+3:20
E
alpha Ari
K2 IIIab
2.0
219
#23  Th-Ar   03:30 ; RV std ;  RH up to 85%
24
3:45
1800
+4:11
E
phi Per
B2 Vep
4.07
125
#25  Th-Ar   04:18
26
4:43
1200
+1:15
E
zeta Tau
B2 IIIpe-sh
3.0
175
/mnt/data is full; delete some files ... #27  Th-Ar 5:09
28
5:24
600
+1:59
E
epsilon Ori
B0Ia
1.7
172
#29 5:37 Th-Ar ... RH is 91%
30
5:53
900
+2:22
E
zeta Ori
O9.5Ib
2.0
190
#31 6:10 Th-Ar
32
6:27
3600
+2:07
E
AX Mon
B2:IIIpshe
6.7
89
Seeing is better but charge transfer problem in ST-7
33
7:30
300

E
Th-Ar

106
has become severe; guiding is difficult. Turn off cooling.
34
7:46
600
+0:11
E
epsilon Leo
G1II
3.0
140
AX Mon exposure looks like a waste of time - too bad.
35
7:59
300

E
Th-Ar

107
Refocused for epsilon Leo.
36
8:21
3600
+0:01
E
HD 91120
B9IV/V
5.6
94
#37 9:24 Th-Ar 
38-42
9:31
0

E
Bias


80
RH 95% - closing.
 43-47  9:48  
Flat      3464
Blank entry under "HA" defaults to zenith.